![]() What Ram Concept features trigger usage of the Ram Concept Post Tension Module license? ![]() Revision 8 posted to RAM | STAAD Wiki by Karl G on 1:44:23 AM This is fixed now and all load combinations are displayed correctly with the loads corresponding to the gravity load cases. RAM Connection for RAM Structural System was showing load conditions with zero loads for load combinations with notional load cases in gravity members.RAM Connection for RAM Structural System was showing the "Not able to orientate local axis" error for some braces.This was fixed and all the seismic information is saved properly. RAM Connection for RAM Structural System was not saving the seismic provisions nor the seismic design category.AISC 360 single plate was showing incorrect results for punching shear in HSS supports due to an error in the single plate length and the bolt eccentricity.The proper factor was considered in order to design and report the correct equation according to the design code year selected. AISC 360 double angle was using an incorrect resistance factor for bolt prying.New CONNECT Licensing which is Bentley’s new process for product activation that allows the user better control over their usage. New AS4100-1998 Australian steel design standard for connection design.Ģ. RAM Connection CONNECT Edition (v13.0.0) Release Notes – Updated December 2018ġ. Revision 1 posted to RAM | STAAD Wiki by Carlos Perez on 10:49:22 PM ProStructures ISM Section and Material Mapping Since STAAD.Pro CONNECT Edition Update 2 this database file is located in C:\Users\\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\PlugIns\StrucLink\Data and it is stored in SQLite database format (.db3). (Please do not refer to the ‘Shapes’ table in the database. We suggest using the user interface to map sections and avoid potential errors manually entering data into the tables however. If one can create entries for mappings in the above tables, then this can be avoided. V8i - C:\SProV8i SS5\STAAD\Plugins\StrucLink\Data\Shapes19S3.mdbĬONNECT edition - C:\ProgramData\Bentley\Engineering\StrucLink\Data If you refer Shapes19S3.mdb, Table ‘ StaadToISMSectionMaps’, you will see the following entries in the table: ![]() If not found, then it pops the mapping dialog for the user to map.īut one thing can be done to avoid the mapping dialog.If not found, STAAD sends the section name to ISM for a lookup.First, STAAD looks into its mapping table to check if its section is associated with ISM.Section mapping in STAAD.pro, using Struclink works as follows: Where are the user selected section and material mapping settings saved for STAAD.pro? Current Revision posted to RAM | STAAD Wiki by Modestas on 10:41:06 AM ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |